ICU VENTILATOR TT27
The ventilator makes a good performance in operation room, ICU department and emergency treatment. It used to assist or replace the spontaneous breathing for adult pediatric and neonatal more than 2kg. Due to the flexible configuration, good quality and competitive price.
FEATURES:
- 15” TFT touch screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
- Multiple ventilation modes, suitable for ICU, emergency department and operation room etc: ( IPPV, A/C, PCV, SIMV,PSV, SPONT/CPAP,SIGH,MANUAL).
- 5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
- Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
- Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.
- Nebulization make medicine into small liquid and particle,easier and quickier for patient to breathe in.
- High temperature resistance breathing circuit is reusable and anti-pollution.
- 14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
- Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration.
- Easy to move with four casters, easy to stop with two brakes.
- Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
- Compact long life internal battery can provide emergency power,avoid risk of patient.
- Self-check before operation,eliminate system mistake.
Specifications
GENERAL PARAMETERS
Ventilation modes: PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL
VENTILATOR PARAMETER RANGES
Tidal volume(Vt): 0 ~ 2000 mL
Frequency (Freq): 1bpm ~ 100 bpm
Oxygen concentration: 21%-100%
I/E: 4:1~1:8
PEEP: 0 cmH2O ~ 40 cmH2O
SIGH: 0 (off) 1 / 100 ~ 5 / 100Pressure
Pressure Triggering sensitivity (Ptr) -20 cmH2O ~ 0 cmH2O (Based on PEEP)
Apnea Ventilation: OFF, 5 s ~ 60 s
Flow Trigger Sensitivity (Ftr): 0.5 L/min ~ 30 L/min
Pressure Control (PC): 5 cmH2O ~ 80 cmH2O
Pressure Support (PS): 0 cmH2O ~ 80 cmH2O
Pressure Control Limit: 20 cmH2O ~ 100 cmH2O
MONITORED PARAMETERS
Frequency (Freq): 0 /min ~ 100 /min
Tidal volume(Vt): 0 mL ~ 2500 mL
MV: 0 L/min ~ 99 L/min
Airway pressure: 0 cmH2O ~ 100 cmH2O
Oxygen concentration: 15 % ~ 100 %
Dynamic lung compliance testing: 1 mL/cmH2O ~ 1000 mL /cmH2O
ALARM AND PROTECTION
The AC power failure alarm: Power failure or no connection
Internal battery backup low voltage alarm: ≤11.3±0.3V
No tidal volume: No tidal volume within 6s
High Minute Volume alarm: 5L/min-99L/min
Low Minute Volume alarm: 1L/min-30L/min
High Airway pressure alarm: 20cmH2O-100cmH2O
Low Airway pressure alarm: 0cmH2O-20cmH2O
High oxygen concentration alarm: 19%-100%
Low oxygen concentration alarm: 18%-99%
Continuous pressure alarm: (PEEP+1.5 cmH2O) over 16s
Suffocation warning: 5-60s
Fan Error: Show on screen
Oxygen Deficit: Show on screen
Maximum Limited Pressure: < 12.5 kPa
WORKING CONDITIONS
Gas source: O2, Air
Pressure: 280kPa-600kPa
Voltage: ~220V ±22V
Power frequency: 50Hz ± 1Hz
Input power:
900 VA (with air compressor)
250 VA (without air compressor)
OSCILLOGRAM
P-T (Pressure Time)
F-T (Flow Time)
V-T (Volume Time)
P-V Loop (Pressure-Volume-Loop)
F-V Loop (Flow-Volume-Loop)
P-F Loop (Pressure-Flow-Loop)
DIMENSIONS
Main Components: 560 x 560 x 605 mm
G.W.: 40 Kg, N.W.: 17 Kg
Air Compressor: 670 x 700 x 1160 mm
G.W.: 84 Kg, N.W.: 46.2 Kg
Certification: CE 0197, ISO 13485, CFDA, FSC