ICU VENTILATOR TT27

The ventilator makes a good performance in operation room, ICU department and emergency treatment. It used to assist or replace the spontaneous breathing for adult pediatric and neonatal more than 2kg. Due to the flexible configuration, good quality and competitive price.

FEATURES:
  • 15” TFT touch screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
  • Multiple ventilation modes, suitable for ICU, emergency department and operation room etc: ( IPPV, A/C, PCV, SIMV,PSV, SPONT/CPAP,SIGH,MANUAL).
  • 5 oscillograms for your choice, 3 of them can be displayed on the screen at the same time.
  • Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
  • Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes.
  • Nebulization make medicine into small liquid and particle,easier and quickier for patient to breathe in.
  • High temperature resistance breathing circuit is reusable and anti-pollution.
  • 14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
  • Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration.
  • Easy to move with four casters, easy to stop with two brakes.
  • Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
  • Compact long life internal battery can provide emergency power,avoid risk of patient.
  • Self-check before operation,eliminate system mistake.

Specifications

GENERAL PARAMETERS

Ventilation modes: PRVC, APRV, DUOLEVEL, V-SIMV, P-SIMV, IPPV, A/C, PCV, PSV, SPONT/CPAP, SIGH, MANUAL

VENTILATOR PARAMETER RANGES

Tidal volume(Vt): 0 ~ 2000 mL

Frequency (Freq): 1bpm ~ 100 bpm

Oxygen concentration: 21%-100%

I/E: 4:1~1:8

PEEP: 0 cmH2O ~ 40 cmH2O

SIGH: 0 (off) 1 / 100 ~ 5 / 100Pressure 

Pressure Triggering sensitivity (Ptr) -20 cmH2O ~ 0 cmH2O (Based on PEEP)

Apnea Ventilation:  OFF, 5 s ~ 60 s

Flow Trigger Sensitivity (Ftr):  0.5 L/min ~ 30 L/min

Pressure Control (PC): 5 cmH2O ~ 80 cmH2O

Pressure Support (PS): 0 cmH2O ~ 80 cmH2O

Pressure Control Limit: 20 cmH2O ~ 100 cmH2O

MONITORED PARAMETERS

Frequency (Freq)0 /min ~ 100 /min

Tidal volume(Vt)0 mL ~ 2500 mL

MV: 0 L/min ~ 99 L/min

Airway pressure: 0 cmH2O ~ 100 cmH2O

Oxygen concentration: 15 % ~ 100 %

Dynamic lung compliance testing: 1 mL/cmH2O ~ 1000 mL /cmH2O

ALARM AND PROTECTION

The AC power failure alarm: Power failure or no connection

Internal battery backup low voltage alarm: ≤11.3±0.3V

No tidal volume: No tidal volume within 6s

High Minute Volume alarm: 5L/min-99L/min

Low Minute Volume alarm: 1L/min-30L/min

High Airway pressure alarm: 20cmH2O-100cmH2O

Low Airway pressure alarm: 0cmH2O-20cmH2O

High oxygen concentration alarm: 19%-100%

Low oxygen concentration alarm: 18%-99%

Continuous pressure alarm: (PEEP+1.5 cmH2O) over 16s

Suffocation warning: 5-60s

Fan Error: Show on screen 

Oxygen Deficit: Show on screen 

Maximum Limited Pressure: < 12.5 kPa 

WORKING CONDITIONS

Gas source: O2, Air

Pressure: 280kPa-600kPa

Voltage: ~220V ±22V

Power frequency: 50Hz ± 1Hz

Input power:

900 VA (with air compressor)

250 VA (without air compressor)

OSCILLOGRAM
P-T (Pressure Time)
F-T (Flow Time)
V-T (Volume Time)
P-V Loop (Pressure-Volume-Loop)
F-V Loop (Flow-Volume-Loop)
P-F Loop (Pressure-Flow-Loop)

 

DIMENSIONS

Main Components: 560 x 560 x 605 mm

G.W.: 40 Kg, N.W.: 17 Kg

Air Compressor: 670 x 700 x 1160 mm

G.W.: 84 Kg, N.W.: 46.2 Kg

 

Certification: CE 0197, ISO 13485, CFDA, FSC

 

 

 

Videos

× How can I help you?